Ultra-high accuracy bonder / Accuracy: ±0.8µm
![]()
This is ultra-high precision thermo-compression (TC) bonder for optical module assembly.
The high-accuracy alignment mechanism ensures ±0.8µm (3 σ).
![]()
The calibration mechanism stabilizes alignment accuracy by detecting the relative positional deviation of the camera used for vision system alignment and feeding back the deviation when alignment for mounting is performed.
With vision system alignment, position accuracy cannot be maintained if the camera position changes because this results in changes in mounting positions as well. The camera is fixed in place and may not seem to be moving, but factors such as use of heating mechanisms and changes in ambient temperature cause the machine to expand/contract, resulting in changes in the camera position over time.
The calibration mechanism therefore offsets such positional changes that occur over time to stabilize alignment accuracy.
This mechanism first performs pattern matching using both the top camera and bottom camera with respect to the same target mark to detect each camera’s deviation from the target mark. By feeding back this deviation when alignment for mounting is performed, the deviation of the camera position is offset.
| Model | FDB210P |
|---|---|
| Applicable product type | VCSEL / LD (Laser Diode) / PD (Photo Diode) / Optical module / LiDAR / etc. |
| Mounting accuracy | ±0.8 µm (3σ) |
| Substrate size | 0.4 mm square to 10.0 mm square |
| Chip size | 0.25 mm square to 6.0 mm square |
| Chip / Substrate supply method | Tray supply, Grip ring |
| Chip heating method | Pulse heat (Max. 450°C) |
| Substrate heating method | Pulse heat (Max. 450°C) |
| Bonding load | 0.1 to 5 N |
| Unit dimensions | 2000 (W) x 1400 (D) x 1700 (H) mm |
| Unit weight | 2,500 kg (Machine only) |
Our ongoing commitment to pioneering the future of technology.